Thomas Kolb 6b070bbf86 Started implementing real charge control
Everything untested so far…
2021-06-07 22:45:17 +02:00
Thomas Kolb 0982f8d7c9 Increase charge pump frequency to 500 Hz
This change reduces the voltage drop with higher loads, for example if
both the solar and the load switch are on at the same time.
2021-06-06 15:08:22 +02:00
Thomas Kolb 3e8ebbe201 Fixed "debug" make target 2021-06-06 12:20:58 +02:00
Thomas Kolb 46d3e16104 Make measurement usable
- Run ADC Calibration on startup (without calibration, there is a huge
  offset error, making the current sensing unusable)
- Added calibration factors which allow to compensate for inaccuracies
  in the circuitry (example: 1% tolerance transistors)
- Send measured values via RS485
2021-06-06 12:17:38 +02:00
Thomas Kolb 2ca6c41260 Implemented RS485 driver (TX only) 2021-06-06 12:16:46 +02:00
Thomas Kolb c01cb4f742 Prepare for analog measurements 2021-06-05 21:20:12 +02:00
Thomas Kolb 6644b29257 Added power switch driver 2021-06-05 16:33:21 +02:00
Thomas Kolb 5764d87a08 Added the charge pump driver 2021-06-05 15:49:29 +02:00
Thomas Kolb 8c317f2904 Initial commit
- Set up build with latest libopencm3
- Created basic project structure
- Implement Charlieplexing for the LEDs and a little test sequence