calibration: add development device
This commit is contained in:
parent
2275edb475
commit
5528259517
|
@ -6,10 +6,24 @@
|
|||
* than the actual voltage, you have to scale by 1.02 and therefore specify
|
||||
* 1020 in this list. */
|
||||
|
||||
/* Values for the device at the B26 tower */
|
||||
|
||||
#if 0
|
||||
#define CAL_FACTOR_U_BAT 994
|
||||
#define CAL_FACTOR_U_SOLAR 997
|
||||
#define CAL_FACTOR_U_SW 996
|
||||
#define CAL_FACTOR_I_SOLAR 1015
|
||||
#define CAL_FACTOR_I_LOAD 1000
|
||||
#endif
|
||||
|
||||
/* Values for the development device */
|
||||
|
||||
#if 1
|
||||
#define CAL_FACTOR_U_BAT 1012
|
||||
#define CAL_FACTOR_U_SOLAR 1015
|
||||
#define CAL_FACTOR_U_SW 1006
|
||||
#define CAL_FACTOR_I_SOLAR 3980
|
||||
#define CAL_FACTOR_I_LOAD 1000
|
||||
#endif
|
||||
|
||||
#endif // CALIBRATION_H
|
||||
|
|