#include <stdbool.h>
#include <fxp.h>
#include "power_switch.h"
#include "measurement.h"
#include "charge_pump.h"
#include "rs485.h"
#include "config.h"
#include "charge_control.h"
static const char *CHARGE_STATE_TEXT[] = {
"WAIT_CHARGEPUMP",
"INITIAL",
"TRANSITION",
"FLOAT",
"SLEEP",
"HIGH_TEMPERATURE"
};
static const char *DISCHARGE_STATE_TEXT[] = {
"WAIT_CHARGEPUMP",
"OK",
"VOLTAGE_LOW",
"OVERCURRENT"
};
static enum ChargeState charge_state;
static enum DischargeState discharge_state;
static bool charge_state_entered;
static bool discharge_state_entered;
static uint64_t charge_state_entered_timestamp;
static uint64_t discharge_state_entered_timestamp;
static fxp_t u_bat_regulation_corridor;
static fxp_t u_bat_initial_full;
static fxp_t u_bat_initial_low;
static fxp_t u_bat_float_full;
static fxp_t u_bat_float_low;
static fxp_t min_charge_pump_excess_voltage;
static fxp_t u_bat_load_on;
static fxp_t u_bat_load_off;
static fxp_t load_current_limit;
static fxp_t internal_temperature_limit;
static fxp_t internal_temperature_recovery;
static fxp_t sleep_solar_current;
static fxp_t sleep_solar_excess_voltage;
static void control_solar_switch(fxp_t u_bat, fxp_t corridor_high, fxp_t corridor_low)
{
if(u_bat >= corridor_high) {
power_switch_solar_off();
} else if(u_bat <= corridor_low) {
power_switch_solar_on();
}
}
static void solar_fsm_update(uint64_t uptime_ms, struct MeasurementResult *meas)
{
uint64_t charge_time_in_state = uptime_ms - charge_state_entered_timestamp;
switch(charge_state) {
case CHARGE_WAIT_CHARGEPUMP:
// force the solar switch off until the charge pump voltage reaches a safe level.
if(charge_state_entered) {
power_switch_solar_off();
}
// calculate charge pump output excess voltage over battery voltage
// and compare to the threshold
if(fxp_sub(meas->u_sw, meas->u_bat) > min_charge_pump_excess_voltage) {
charge_state = CHARGE_INITIAL;
}
break;
case CHARGE_INITIAL:
control_solar_switch(meas->u_bat, u_bat_initial_full, u_bat_initial_low);
// temperature limit
if(meas->temperature > internal_temperature_limit) {
charge_state = CHARGE_HIGH_TEMPERATURE;
}
// time limit for initial charging
if(charge_time_in_state > INITIAL_CHARGE_HOLD_TIME) {
charge_state = CHARGE_TRANSITION;
}
// low-current limit (go to sleep at night)
if(meas->i_solar < sleep_solar_current) {
charge_state = CHARGE_SLEEP;
}
break;
case CHARGE_TRANSITION:
// FIXME: dynamically adjust thresholds
control_solar_switch(meas->u_bat, u_bat_float_full, u_bat_float_low);
// temperature limit
if(meas->temperature > internal_temperature_limit) {
charge_state = CHARGE_HIGH_TEMPERATURE;
}
// time limit for transition to float charging
if(charge_time_in_state > INITIAL_TO_FLOAT_TRANSITION_TIME) {
charge_state = CHARGE_FLOAT;
}
// low-current limit (go to sleep at night)
if(meas->i_solar < sleep_solar_current) {
charge_state = CHARGE_SLEEP;
}
break;
case CHARGE_FLOAT:
control_solar_switch(meas->u_bat, u_bat_float_full, u_bat_float_low);
// temperature limit
if(meas->temperature > internal_temperature_limit) {
charge_state = CHARGE_HIGH_TEMPERATURE;
}
// low-current limit (go to sleep at night)
if(meas->i_solar < sleep_solar_current) {
charge_state = CHARGE_SLEEP;
}
break;
case CHARGE_SLEEP:
if(charge_state_entered) {
power_switch_solar_off();
}
{
fxp_t solar_excess_voltage = fxp_sub(meas->u_solar, meas->u_bat);
if(solar_excess_voltage > sleep_solar_excess_voltage) {
// resume operation
charge_state = CHARGE_WAIT_CHARGEPUMP;
}
}
break;
case CHARGE_HIGH_TEMPERATURE:
if(charge_state_entered) {
power_switch_solar_off();
}
if(meas->temperature < internal_temperature_recovery) {
charge_state = CHARGE_WAIT_CHARGEPUMP;
}
break;
default:
// unknown state
break;
}
}
static void load_fsm_update(uint64_t uptime_ms, struct MeasurementResult *meas)
{
uint64_t discharge_time_in_state = uptime_ms - discharge_state_entered_timestamp;
switch(discharge_state) {
case DISCHARGE_WAIT_CHARGEPUMP:
// force the load off until the charge pump voltage reaches a safe level.
if(discharge_state_entered) {
power_switch_load_off();
}
// calculate charge pump output excess voltage over battery voltage
// and compare to the threshold
if(fxp_sub(meas->u_sw, meas->u_bat) > min_charge_pump_excess_voltage) {
discharge_state = DISCHARGE_VOLTAGE_LOW;
}
break;
case DISCHARGE_OK:
// Battery voltage is in a safe range, so keep the load switched on
if(discharge_state_entered) {
power_switch_load_on();
}
if(meas->i_load > load_current_limit) {
// TODO: maybe only check this 10 ms after load is switched on
// to allow for inrush current?
discharge_state = DISCHARGE_OVERCURRENT;
}
if(meas->u_bat < u_bat_load_off) {
discharge_state = DISCHARGE_VOLTAGE_LOW;
}
break;
case DISCHARGE_VOLTAGE_LOW:
// Battery voltage is too low, so keep the load switched off
if(discharge_state_entered) {
power_switch_load_off();
}
// Can only switch on again after a specific amount of time has passed
if((meas->u_bat > u_bat_load_on)
&& (discharge_time_in_state > LOAD_ON_DELAY)) {
discharge_state = DISCHARGE_OK;
}
break;
case DISCHARGE_OVERCURRENT:
// Battery voltage is too low, so keep the load switched off
if(discharge_state_entered) {
power_switch_load_off();
}
// no way out except reset
break;
default:
// unknown state
break;
}
}
void charge_control_init(void)
{
charge_state = CHARGE_WAIT_CHARGEPUMP;
discharge_state = DISCHARGE_WAIT_CHARGEPUMP;
charge_state_entered = true;
discharge_state_entered = true;
/* calculate thresholds */
u_bat_regulation_corridor = fxp_div(FXP_FROM_INT(U_BAT_REGULATION_CORRIDOR),
FXP_FROM_INT(1000));
u_bat_initial_full = fxp_div(FXP_FROM_INT(U_BAT_INITAL_FULL), FXP_FROM_INT(1000));
u_bat_initial_low = fxp_sub(u_bat_initial_full, u_bat_regulation_corridor);
u_bat_float_full = fxp_div(FXP_FROM_INT(U_BAT_FLOAT_FULL), FXP_FROM_INT(1000));
u_bat_float_low = fxp_sub(u_bat_float_full, u_bat_regulation_corridor);
min_charge_pump_excess_voltage = fxp_div(FXP_FROM_INT(MIN_CHARGE_PUMP_EXCESS_VOLTAGE),
FXP_FROM_INT(1000));
u_bat_load_on = fxp_div(FXP_FROM_INT(U_BAT_LOAD_ON), FXP_FROM_INT(1000));
u_bat_load_off = fxp_div(FXP_FROM_INT(U_BAT_LOAD_OFF), FXP_FROM_INT(1000));
load_current_limit = fxp_div(FXP_FROM_INT(LOAD_CURRENT_LIMIT_MA), FXP_FROM_INT(1000));
internal_temperature_limit = fxp_div(FXP_FROM_INT(INTERNAL_TEMPERATURE_LIMIT), FXP_FROM_INT(10));
internal_temperature_recovery = fxp_div(FXP_FROM_INT(INTERNAL_TEMPERATURE_RECOVERY), FXP_FROM_INT(10));
sleep_solar_current = fxp_div(FXP_FROM_INT(SLEEP_SOLAR_CURRENT), FXP_FROM_INT(1000));
sleep_solar_excess_voltage = fxp_div(FXP_FROM_INT(SLEEP_SOLAR_EXCESS_VOLTAGE), FXP_FROM_INT(1000));
}
void charge_control_update(uint64_t uptime_ms, struct MeasurementResult *meas)
{
/* state change tracking for efficient transistions. */
enum ChargeState last_charge_state = charge_state;
enum DischargeState last_discharge_state = discharge_state;
if(charge_state_entered) {
rs485_enqueue("STATE:CHARGE:");
rs485_enqueue(CHARGE_STATE_TEXT[charge_state]);
rs485_enqueue("\n");
charge_state_entered_timestamp = uptime_ms;
}
if(discharge_state_entered) {
rs485_enqueue("STATE:DISCHG:");
rs485_enqueue(DISCHARGE_STATE_TEXT[discharge_state]);
rs485_enqueue("\n");
discharge_state_entered_timestamp = uptime_ms;
}
/* generalized charge pump control */
if(charge_state_entered || discharge_state_entered) {
if(charge_state == CHARGE_WAIT_CHARGEPUMP
|| discharge_state == DISCHARGE_WAIT_CHARGEPUMP) {
// either charge or discharge control is waiting for the charge
// pump, so power it up!
charge_pump_start();
} else if((charge_state == CHARGE_SLEEP)
&& (discharge_state == DISCHARGE_VOLTAGE_LOW)) {
// no power from the solar panel and the battery voltage is too
// low, so both switches are off and we can safely stop the charge
// pump
charge_pump_stop();
}
}
solar_fsm_update(uptime_ms, meas);
load_fsm_update(uptime_ms, meas);
charge_state_entered = charge_state != last_charge_state;
discharge_state_entered = discharge_state != last_discharge_state;
}
bool charge_control_is_idle(void)
{
return ((charge_state == CHARGE_SLEEP)
&& (discharge_state == DISCHARGE_VOLTAGE_LOW));
}
bool charge_control_is_charge_blocked(void)
{
switch(charge_state) {
case CHARGE_HIGH_TEMPERATURE:
case CHARGE_WAIT_CHARGEPUMP:
return true;
default:
return false;
}
}
bool charge_control_is_discharge_blocked(void)
{
switch(discharge_state) {
case DISCHARGE_OVERCURRENT:
case DISCHARGE_WAIT_CHARGEPUMP:
return true;
default:
return false;
}
}