#ifndef CONFIG_H
#define CONFIG_H
/* Thresholds for charging control */
/* Battery regulation corridor width (in mV). */
#define U_BAT_REGULATION_CORRIDOR 100
/* Initial charge battery voltage threshold (in mV). */
#define U_BAT_INITIAL_FULL 28600 // stop charging if battery voltage reaches this threshold
/* Cancel initial charge voltage hold below this battery voltage (in mV). */
#define U_BAT_INITIAL_HOLD_CANCEL 27000
/* Transition to floating voltage levels after this time (in ms). */
#define INITIAL_CHARGE_HOLD_TIME 1800000
/* Duration of the transistion from initial charging to float (in ms). */
#define INITIAL_TO_FLOAT_TRANSITION_TIME 600000
/* Float charge battery voltage threshold (in mV). */
#define U_BAT_FLOAT_FULL 27600 // stop charging if battery voltage reaches this threshold
/* Minimum voltage difference to U_bat that the solar panels must produce
* before charging is resumed after it was switched off (in mV). */
#define SLEEP_SOLAR_EXCESS_VOLTAGE 1000
/* Minimum charge current required before charging is stopped to save power at
* the charge pump (in mA). */
#define SLEEP_SOLAR_CURRENT 1
/* Delay between state change and sleep state check (in ms). */
#define SLEEP_STATE_DELAY 60000
/* Delay between charging switch state change and sleep state check(in ms). */
#define SLEEP_SWITCH_DELAY 1000
/* Maximum allowed microcontroller temperature (in units of 0.1 °C). If this
* temperature is exceeded, charging is stopped. The load is kept on. Do not
* set this too high as the heat has to propagate from the power MOSFETs. */
#define INTERNAL_TEMPERATURE_LIMIT 500
/* Resume operation below this temperature (in units of 0.1 °C). */
#define INTERNAL_TEMPERATURE_RECOVERY 450
/* Thresholds for load control */
/* Voltage above which the load is turned on (in mV). */
#define U_BAT_LOAD_ON 27000
/* Voltage below which the load is turned off (in mV). */
#define U_BAT_LOAD_OFF 24000
/* Current at which the overload protection triggers (in mA). */
#define LOAD_CURRENT_LIMIT_MA 10000
/* Inrush tolerance time (in ms). Overload protection is not enforced for this
* time after load power-on. */
#define LOAD_CURRENT_INRUSH_TIME 10
/* Minimum voltage that the charge pump must produce above U_bat before any
* power FET is switched on (in mV). */
#define MIN_CHARGE_PUMP_EXCESS_VOLTAGE 10000
/* The minimum time the load must be off before it can be switched on again (in ms). */
#define LOAD_ON_DELAY 10000
/* Measurement Averaging:
* Alpha is specified in units of 1/1000. 1000 means that only the latest
* value is relevant, 0 means that the measurement has no influence. The latter
* is useless.
*
* The formula to calculate the next averaged value avg from a measurement meas is:
* avg[k] = meas * (alpha/1000) + avg[k-1] * (1 - alpha/1000)
*
* For overload protection (battery voltage, load current), the latest values
* are always used.
* */
/* Averaging factor for load current. */
#define AVG_ALPHA_I_SOLAR 10
#define AVG_ALPHA_I_LOAD 10
#define AVG_ALPHA_U_BAT 100
#define AVG_ALPHA_U_SW 100
#define AVG_ALPHA_U_SOLAR 100
#define AVG_ALPHA_TEMP 10
/* Generic configuration */
/* Time (in ms) to stay active in idle state before entering deep sleep. */
#define DEEPSLEEP_DELAY 1000
/* Deep sleep duration (in seconds). */
#define DEEPSLEEP_DURATION 10
#endif // CONFIG_H