LNSC-2420-Firmware/src/charge_control.c

490 lines
13 KiB
C
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

#include <stdbool.h>
#include <fxp.h>
#include "bmp280.h"
#include "power_switch.h"
#include "measurement.h"
#include "charge_pump.h"
#include "rs485.h"
#include "flash_config.h"
#include "addon_io.h"
#include "charge_control.h"
static const char *CHARGE_STATE_TEXT[CHARGE_NUM_STATES] = {
"WAIT_CHARGEPUMP",
"INITIAL",
"INITIAL_HOLD",
"TRANSITION",
"FLOAT",
"SLEEP",
"HIGH_INTERNAL_TEMPERATURE",
"LOW_EXTERNAL_TEMPERATURE"
};
static const char *DISCHARGE_STATE_TEXT[DISCHARGE_NUM_STATES] = {
"WAIT_CHARGEPUMP",
"OK",
"VOLTAGE_LOW",
"OVERCURRENT",
"OVERCURRENT_DELAY"
};
static enum ChargeState charge_state;
static enum DischargeState discharge_state;
static bool charge_state_entered;
static bool discharge_state_entered;
static uint64_t charge_state_entered_timestamp;
static uint64_t discharge_state_entered_timestamp;
static fxp_t u_bat_regulation_corridor;
static fxp_t u_bat_initial_full;
static fxp_t u_bat_initial_low;
static fxp_t u_bat_initial_hold_cancel;
static fxp_t u_bat_float_full;
static fxp_t u_bat_float_low;
static fxp_t min_charge_pump_excess_voltage;
static fxp_t u_bat_load_on;
static fxp_t u_bat_load_off;
static fxp_t load_current_limit;
static fxp_t load_current_limit_delay;
static fxp_t internal_temperature_limit;
static fxp_t internal_temperature_recovery;
static fxp_t external_temperature_limit;
static fxp_t external_temperature_recovery;
static fxp_t sleep_solar_current;
static fxp_t sleep_solar_excess_voltage;
static uint32_t overload_retry_time;
static enum ChargeState control_solar_charging(
fxp_t corridor_high,
fxp_t corridor_low,
uint64_t uptime_ms,
struct MeasurementResult *meas,
enum ChargeState current_state,
uint64_t time_in_state)
{
static uint64_t last_switch_change_time = 0;
uint64_t solar_switch_onoff_duration = uptime_ms - last_switch_change_time;
bool last_switch_state = power_switch_solar_status();
if(meas->u_bat >= corridor_high) {
power_switch_solar_off();
} else if(meas->u_bat <= corridor_low) {
power_switch_solar_on();
}
bool current_switch_state = power_switch_solar_status();
if(last_switch_state != current_switch_state) { // switch changed
last_switch_change_time = uptime_ms;
solar_switch_onoff_duration = 0;
}
// internal temperature limit: prevent overheating of the power transistors.
if(meas->avg_temperature > internal_temperature_limit) {
return CHARGE_HIGH_INTERNAL_TEMPERATURE;
}
// external temperature limit: prevent charging the battery if temperature is too low.
if(bmp280_are_measurements_valid() &&
bmp280_get_temperature() < external_temperature_limit) {
return CHARGE_LOW_EXTERNAL_TEMPERATURE;
}
// low-current limit (go to sleep at night)
if((time_in_state > FLASH_CONFIG_SLEEP_STATE_DELAY)
&& (current_switch_state == true)
&& (solar_switch_onoff_duration > FLASH_CONFIG_SLEEP_SWITCH_DELAY)
&& (meas->avg_i_solar < sleep_solar_current)) {
return CHARGE_SLEEP;
}
return current_state;
}
static void solar_fsm_update(uint64_t uptime_ms, struct MeasurementResult *meas)
{
uint64_t charge_time_in_state = uptime_ms - charge_state_entered_timestamp;
switch(charge_state) {
case CHARGE_WAIT_CHARGEPUMP:
// force the solar switch off until the charge pump voltage reaches a safe level.
if(charge_state_entered) {
power_switch_solar_off();
}
// calculate charge pump output excess voltage over battery voltage
// and compare to the threshold
if(fxp_sub(meas->u_sw, meas->u_bat) > min_charge_pump_excess_voltage) {
charge_state = CHARGE_INITIAL;
}
break;
case CHARGE_INITIAL:
charge_state = control_solar_charging(
u_bat_initial_full,
u_bat_initial_low,
uptime_ms,
meas,
charge_state,
charge_time_in_state);
// switch to hold state when high threshold is reached
if(meas->u_bat >= u_bat_initial_full) {
charge_state = CHARGE_INITIAL_HOLD;
}
break;
case CHARGE_INITIAL_HOLD:
charge_state = control_solar_charging(
u_bat_initial_full,
u_bat_initial_low,
uptime_ms,
meas,
charge_state,
charge_time_in_state);
// cancel charge hold if battery voltage is below threshold
if(meas->u_bat <= u_bat_initial_hold_cancel) {
charge_state = CHARGE_INITIAL;
}
// time limit for initial hold charging
if(charge_time_in_state > FLASH_CONFIG_INITIAL_CHARGE_HOLD_TIME) {
charge_state = CHARGE_TRANSITION;
}
break;
case CHARGE_TRANSITION:
if(charge_time_in_state < FLASH_CONFIG_INITIAL_TO_FLOAT_TRANSITION_TIME) {
// dynamically adjust thresholds
fxp_t u_bat_full =
fxp_add(u_bat_initial_full,
fxp_mult(
fxp_sub(u_bat_float_full, u_bat_initial_full),
fxp_div(charge_time_in_state, FLASH_CONFIG_INITIAL_TO_FLOAT_TRANSITION_TIME)));
fxp_t u_bat_low = fxp_sub(u_bat_full, u_bat_regulation_corridor);
charge_state = control_solar_charging(
u_bat_full,
u_bat_low,
uptime_ms,
meas,
charge_state,
charge_time_in_state);
} else {
// time limit for transition to float charging reached
charge_state = CHARGE_FLOAT;
break;
}
break;
case CHARGE_FLOAT:
charge_state = control_solar_charging(
u_bat_float_full,
u_bat_float_low,
uptime_ms,
meas,
charge_state,
charge_time_in_state);
// temperature limit
if(meas->temperature > internal_temperature_limit) {
charge_state = CHARGE_HIGH_INTERNAL_TEMPERATURE;
break;
}
break;
case CHARGE_SLEEP:
if(charge_state_entered) {
power_switch_solar_off();
}
{
fxp_t solar_excess_voltage = fxp_sub(meas->u_solar, meas->u_bat);
if(solar_excess_voltage > sleep_solar_excess_voltage) {
// resume operation
charge_state = CHARGE_WAIT_CHARGEPUMP;
break;
}
}
break;
case CHARGE_HIGH_INTERNAL_TEMPERATURE:
if(charge_state_entered) {
power_switch_solar_off();
}
if(meas->temperature < internal_temperature_recovery) {
charge_state = CHARGE_WAIT_CHARGEPUMP;
break;
}
break;
case CHARGE_LOW_EXTERNAL_TEMPERATURE:
if(charge_state_entered) {
power_switch_solar_off();
// switch on the heater via the isolated I/O addon board
addon_io_iso_out_on(0);
}
// this state can only be entered if the BMP280 measurement is valid, so
// no need to check it again here.
if(bmp280_get_temperature() > external_temperature_recovery) {
charge_state = CHARGE_WAIT_CHARGEPUMP;
// switch the heater off again when this state is left
addon_io_iso_out_off(0);
break;
}
break;
default:
// unknown state
break;
}
}
static void load_fsm_update(uint64_t uptime_ms, struct MeasurementResult *meas)
{
uint64_t discharge_time_in_state = uptime_ms - discharge_state_entered_timestamp;
switch(discharge_state) {
case DISCHARGE_WAIT_CHARGEPUMP:
// force the load off until the charge pump voltage reaches a safe level.
if(discharge_state_entered) {
power_switch_load_off();
}
// calculate charge pump output excess voltage over battery voltage
// and compare to the threshold
if(fxp_sub(meas->u_sw, meas->u_bat) > min_charge_pump_excess_voltage) {
discharge_state = DISCHARGE_OK;
}
break;
case DISCHARGE_OK:
// Battery voltage is in a safe range, so keep the load switched on
if(discharge_state_entered) {
power_switch_load_on();
}
if((meas->i_load > load_current_limit)
&& (discharge_time_in_state > FLASH_CONFIG_LOAD_CURRENT_INRUSH_TIME)) {
if(load_current_limit_delay == 0) {
// switch off immediately
power_switch_load_off();
discharge_state = DISCHARGE_OVERCURRENT;
} else {
discharge_state = DISCHARGE_OVERCURRENT_DELAY;
}
}
if((overload_retry_time != FLASH_CONFIG_OVERLOAD_RETRY_TIME) &&
(discharge_time_in_state > 300000)) {
// overload did not trigger for 5 minutes, so we assume its stable and
// reset the retry time delay.
overload_retry_time = FLASH_CONFIG_OVERLOAD_RETRY_TIME;
}
if(meas->avg_u_bat < u_bat_load_off) {
discharge_state = DISCHARGE_VOLTAGE_LOW;
}
break;
case DISCHARGE_VOLTAGE_LOW:
// Battery voltage is too low, so keep the load switched off
if(discharge_state_entered) {
power_switch_load_off();
}
// Can only switch on again after a specific amount of time has passed
if((meas->avg_u_bat > u_bat_load_on)
&& (discharge_time_in_state > FLASH_CONFIG_LOAD_ON_DELAY)) {
discharge_state = DISCHARGE_WAIT_CHARGEPUMP;
}
break;
case DISCHARGE_OVERCURRENT_DELAY:
if(meas->i_load < load_current_limit) {
// current recovered
discharge_state = DISCHARGE_OK;
} else if(discharge_time_in_state >= FLASH_CONFIG_OVERLOAD_DELAY_TIME) {
// switch off immediately
power_switch_load_off();
discharge_state = DISCHARGE_OVERCURRENT;
}
break;
case DISCHARGE_OVERCURRENT:
// Current limit reached
if(discharge_state_entered) {
power_switch_load_off();
}
// Overload recovery
if(discharge_time_in_state >= overload_retry_time) {
// double the overload retry time for the next turn if it is less than 7 days
if(overload_retry_time < (7*24*3600*1000)) {
overload_retry_time *= 2;
}
discharge_state = DISCHARGE_WAIT_CHARGEPUMP;
}
break;
default:
// unknown state
break;
}
}
void charge_control_init(void)
{
charge_state = CHARGE_WAIT_CHARGEPUMP;
discharge_state = DISCHARGE_WAIT_CHARGEPUMP;
charge_state_entered = true;
discharge_state_entered = true;
/* calculate thresholds */
u_bat_regulation_corridor = fxp_div(FXP_FROM_INT(FLASH_CONFIG_U_BAT_REGULATION_CORRIDOR),
FXP_FROM_INT(1000));
u_bat_initial_full = fxp_div(FXP_FROM_INT(FLASH_CONFIG_U_BAT_INITIAL_FULL), FXP_FROM_INT(1000));
u_bat_initial_low = fxp_sub(u_bat_initial_full, u_bat_regulation_corridor);
u_bat_initial_hold_cancel = fxp_div(FXP_FROM_INT(FLASH_CONFIG_U_BAT_INITIAL_HOLD_CANCEL), FXP_FROM_INT(1000));
u_bat_float_full = fxp_div(FXP_FROM_INT(FLASH_CONFIG_U_BAT_FLOAT_FULL), FXP_FROM_INT(1000));
u_bat_float_low = fxp_sub(u_bat_float_full, u_bat_regulation_corridor);
min_charge_pump_excess_voltage = fxp_div(FXP_FROM_INT(FLASH_CONFIG_MIN_CHARGE_PUMP_EXCESS_VOLTAGE),
FXP_FROM_INT(1000));
u_bat_load_on = fxp_div(FXP_FROM_INT(FLASH_CONFIG_U_BAT_LOAD_ON), FXP_FROM_INT(1000));
u_bat_load_off = fxp_div(FXP_FROM_INT(FLASH_CONFIG_U_BAT_LOAD_OFF), FXP_FROM_INT(1000));
load_current_limit = fxp_div(FXP_FROM_INT(FLASH_CONFIG_LOAD_CURRENT_LIMIT_MA), FXP_FROM_INT(1000));
internal_temperature_limit = fxp_div(FXP_FROM_INT(FLASH_CONFIG_INTERNAL_TEMPERATURE_LIMIT), FXP_FROM_INT(10));
internal_temperature_recovery = fxp_div(FXP_FROM_INT(FLASH_CONFIG_INTERNAL_TEMPERATURE_RECOVERY), FXP_FROM_INT(10));
external_temperature_limit = fxp_div(FXP_FROM_INT(FLASH_CONFIG_EXTERNAL_TEMPERATURE_LIMIT), FXP_FROM_INT(10));
external_temperature_recovery = fxp_div(FXP_FROM_INT(FLASH_CONFIG_EXTERNAL_TEMPERATURE_RECOVERY), FXP_FROM_INT(10));
sleep_solar_current = fxp_div(FXP_FROM_INT(FLASH_CONFIG_SLEEP_SOLAR_CURRENT), FXP_FROM_INT(1000));
sleep_solar_excess_voltage = fxp_div(FXP_FROM_INT(FLASH_CONFIG_SLEEP_SOLAR_EXCESS_VOLTAGE), FXP_FROM_INT(1000));
overload_retry_time = FLASH_CONFIG_OVERLOAD_RETRY_TIME;
}
void charge_control_update(uint64_t uptime_ms, struct MeasurementResult *meas)
{
/* state change tracking for efficient transistions. */
enum ChargeState last_charge_state = charge_state;
enum DischargeState last_discharge_state = discharge_state;
if(charge_state_entered) {
rs485_enqueue("STATE:CHARGE:");
rs485_enqueue(CHARGE_STATE_TEXT[charge_state]);
rs485_enqueue("\n");
charge_state_entered_timestamp = uptime_ms;
}
if(discharge_state_entered) {
rs485_enqueue("STATE:DISCHG:");
rs485_enqueue(DISCHARGE_STATE_TEXT[discharge_state]);
rs485_enqueue("\n");
discharge_state_entered_timestamp = uptime_ms;
}
/* generalized charge pump control */
if(charge_state_entered || discharge_state_entered) {
if(charge_state == CHARGE_WAIT_CHARGEPUMP
|| discharge_state == DISCHARGE_WAIT_CHARGEPUMP) {
// either charge or discharge control is waiting for the charge
// pump, so power it up!
charge_pump_start();
} else if(((charge_state == CHARGE_SLEEP) || charge_control_is_charge_blocked())
&& ((discharge_state == DISCHARGE_VOLTAGE_LOW) || charge_control_is_discharge_blocked())) {
// no power from the solar panel and the battery voltage is too
// low, so both switches are off and we can safely stop the charge
// pump
charge_pump_stop();
}
}
solar_fsm_update(uptime_ms, meas);
load_fsm_update(uptime_ms, meas);
charge_state_entered = charge_state != last_charge_state;
discharge_state_entered = discharge_state != last_discharge_state;
}
bool charge_control_is_idle(void)
{
return (((charge_state == CHARGE_SLEEP)
|| (charge_state == CHARGE_HIGH_INTERNAL_TEMPERATURE)
|| (charge_state == CHARGE_LOW_EXTERNAL_TEMPERATURE))
&& ((discharge_state == DISCHARGE_VOLTAGE_LOW)
|| (discharge_state == DISCHARGE_OVERCURRENT)));
}
bool charge_control_is_charge_blocked(void)
{
switch(charge_state) {
case CHARGE_HIGH_INTERNAL_TEMPERATURE:
case CHARGE_LOW_EXTERNAL_TEMPERATURE:
case CHARGE_WAIT_CHARGEPUMP:
return true;
default:
return false;
}
}
bool charge_control_is_discharge_blocked(void)
{
switch(discharge_state) {
case DISCHARGE_OVERCURRENT:
case DISCHARGE_WAIT_CHARGEPUMP:
return true;
default:
return false;
}
}