2021-06-07 22:45:17 +02:00
|
|
|
#ifndef CONFIG_H
|
|
|
|
#define CONFIG_H
|
|
|
|
|
|
|
|
/* Thresholds for charging control */
|
|
|
|
|
|
|
|
/* Battery regulation corridor width (in mV). */
|
|
|
|
#define U_BAT_REGULATION_CORRIDOR 100
|
|
|
|
|
|
|
|
/* Initial charge battery voltage threshold (in mV). */
|
|
|
|
#define U_BAT_INITAL_FULL 28800 // stop charging if battery voltage reaches this threshold
|
|
|
|
|
|
|
|
/* Transition to floating voltage levels after this time (in ms). */
|
|
|
|
#define INITIAL_CHARGE_HOLD_TIME 3600000
|
|
|
|
|
|
|
|
/* Duration of the transistion from initial charging to float (in ms). */
|
|
|
|
#define INITIAL_TO_FLOAT_TRANSITION_TIME 600000
|
|
|
|
|
|
|
|
/* Float charge battery voltage threshold (in mV). */
|
|
|
|
#define U_BAT_FLOAT_FULL 27600 // stop charging if battery voltage reaches this threshold
|
|
|
|
|
|
|
|
/* Minimum voltage difference to U_bat that the solar panels must produce
|
|
|
|
* before charging is resumed after it was switched off (in mV). */
|
|
|
|
#define SLEEP_SOLAR_EXCESS_VOLTAGE 1000
|
|
|
|
|
|
|
|
/* Minimum charge current required before charging is stopped to save power at
|
|
|
|
* the charge pump (in mA). */
|
|
|
|
#define SLEEP_SOLAR_CURRENT 5
|
|
|
|
|
|
|
|
/* Maximum allowed microcontroller temperature (in units of 0.1 °C). If this
|
|
|
|
* temperature is exceeded, charging is stopped. The load is kept on. Do not
|
|
|
|
* set this too high as the heat has to propagate from the power MOSFETs. */
|
|
|
|
#define INTERNAL_TEMPERATURE_LIMIT 500
|
|
|
|
|
|
|
|
/* Resume operation below this temperature (in units of 0.1 °C). */
|
|
|
|
#define INTERNAL_TEMPERATURE_RECOVERY 450
|
|
|
|
|
|
|
|
|
|
|
|
/* Thresholds for load control */
|
|
|
|
|
|
|
|
/* Voltage above which the load is turned on (in mV). */
|
|
|
|
#define U_BAT_LOAD_ON 27000
|
|
|
|
/* Voltage below which the load is turned off (in mV). */
|
|
|
|
#define U_BAT_LOAD_OFF 24000
|
|
|
|
|
|
|
|
/* Current at which the overload protection triggers (in mA). */
|
|
|
|
#define LOAD_CURRENT_LIMIT_MA 10000
|
|
|
|
|
|
|
|
/* Minimum voltage that the charge pump must produce above U_bat before any
|
|
|
|
* power FET is switched on (in mV). */
|
|
|
|
#define MIN_CHARGE_PUMP_EXCESS_VOLTAGE 10000
|
|
|
|
|
|
|
|
/* The minimum time the load must be off before it can be switched on again (in ms). */
|
|
|
|
#define LOAD_ON_DELAY 10000
|
|
|
|
|
2021-06-11 23:56:12 +02:00
|
|
|
|
|
|
|
/* Generic configuration */
|
|
|
|
|
|
|
|
/* Time (in ms) to stay active in idle state before entering deep sleep. */
|
2021-06-12 15:57:19 +02:00
|
|
|
#define DEEPSLEEP_DELAY 1000
|
2021-06-11 23:56:12 +02:00
|
|
|
|
|
|
|
/* Deep sleep duration (in seconds). */
|
|
|
|
#define DEEPSLEEP_DURATION 10
|
|
|
|
|
2021-06-07 22:45:17 +02:00
|
|
|
#endif // CONFIG_H
|