# Values for the development device
calibration:
# Calibration factor defined here are divided by 1000 to determine the actual
# scaling factor. Therefore, if the voltage determined by the firmware is 2%
# lower than the actual voltage, you have to scale by 1.02 and therefore
# specify 1020 in this list.
CAL_FACTOR_U_BAT: 1012
CAL_FACTOR_U_SOLAR: 1015
CAL_FACTOR_U_SW: 1006
CAL_FACTOR_I_SOLAR: 3980
CAL_FACTOR_I_LOAD: 1000
config:
# Thresholds for charging control
# Battery regulation corridor width (in mV).
U_BAT_REGULATION_CORRIDOR: 100
# Initial charge battery voltage threshold (in mV).
# stop charging if battery voltage reaches this threshold
U_BAT_INITIAL_FULL: 28600
# Cancel initial charge voltage hold below this battery voltage (in mV).
U_BAT_INITIAL_HOLD_CANCEL: 27000
# Transition to floating voltage levels after this time (in ms).
INITIAL_CHARGE_HOLD_TIME: 1800000
# Duration of the transistion from initial charging to float (in ms).
INITIAL_TO_FLOAT_TRANSITION_TIME: 600000
# Float charge battery voltage threshold (in mV).
# stop charging if battery voltage reaches this threshold
U_BAT_FLOAT_FULL: 27600
# Minimum voltage difference to U_bat that the solar panels must produce
# before charging is resumed after it was switched off (in mV).
SLEEP_SOLAR_EXCESS_VOLTAGE: 1000
# Minimum charge current required before charging is stopped to save power at
# the charge pump (in mA).
SLEEP_SOLAR_CURRENT: 1
# Delay between state change and sleep state check (in ms).
SLEEP_STATE_DELAY: 60000
# Delay between charging switch state change and sleep state check(in ms).
SLEEP_SWITCH_DELAY: 1000
# Maximum allowed microcontroller temperature (in units of 0.1 °C). If this
# temperature is exceeded, charging is stopped. The load is kept on. Do not
# set this too high as the heat has to propagate from the power MOSFETs.
INTERNAL_TEMPERATURE_LIMIT: 500
# Resume operation below this temperature (in units of 0.1 °C).
INTERNAL_TEMPERATURE_RECOVERY: 450
# Thresholds for load control
# Voltage above which the load is turned on (in mV).
U_BAT_LOAD_ON: 27000
# Voltage below which the load is turned off (in mV).
U_BAT_LOAD_OFF: 24000
# Current at which the overload protection triggers (in mA).
LOAD_CURRENT_LIMIT_MA: 10000
# Inrush tolerance time (in ms). Overload protection is not enforced for this
# time after load power-on.
LOAD_CURRENT_INRUSH_TIME: 10
# Minimum voltage that the charge pump must produce above U_bat before any
# power FET is switched on (in mV).
MIN_CHARGE_PUMP_EXCESS_VOLTAGE: 10000
# The minimum time the load must be off before it can be switched on again (in ms).
LOAD_ON_DELAY: 10000
# Measurement Averaging:
# Alpha is specified in units of 1/1000. 1000 means that only the latest
# value is relevant, 0 means that the measurement has no influence. The latter
# is useless.
#
# The formula to calculate the next averaged value avg from a measurement meas is:
# avg[k] = meas * (alpha/1000) + avg[k-1] * (1 alpha/1000)
#
# For overload protection (battery voltage, load current), the latest values
# are always used.
# Averaging factor for load current.
AVG_ALPHA_I_SOLAR: 10
AVG_ALPHA_I_LOAD: 10
AVG_ALPHA_U_BAT: 100
AVG_ALPHA_U_SW: 100
AVG_ALPHA_U_SOLAR: 100
AVG_ALPHA_TEMP: 10
# Generic configuration
# Time (in ms) to stay active in idle state before entering deep sleep.
DEEPSLEEP_DELAY: 1000
# Deep sleep duration (in seconds).
DEEPSLEEP_DURATION: 10